Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

explain me how a power factor is improved by adding a
capacitor?what capacitor do to improve it?in simple words
and in detail?thx

Answer Posted / mohan

An electrical load can be inductive or resistive(filament
bulb).
for an inductive load the energization power is required ,
isnce this is called reactive power(imaginary magantising
power) , which is non productive.
You can draw paralles to your Savings Bank account - where
you need to maintain certain amount as minimum balance,
which you can not withdraw.

again this "magnatising current" is load dependant and will
varry according to the load. for example if you are riding
a bicycle , the minimum force needed to be given for moving
the cycle must be higher than than Weights(your+Cycle)
*gravitation force.
The base value weight* gravitational force can be imagined
as reactive power and, when you ride the cycle in elevated
path u put extra energy and on a slope u need less energy.
Capacitor is a supplier of reactive energy and if you use
capacitor to compliment the reactive power then you will
have reduced kva withdrawal from grid.
KVA = SQRT[kw*kw)+(kvar*kvar)]
PF = kw/kva. in other words PF is the efficincy of yor
power conversion. since it is the ratio of output(KW you
consume ) to the input(the withdrawal from grid)

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

1962


How to calculate the heat load for a electrical room

3073


What are electric motors?

1154


What is meant by reset level of the relay?

1200


How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?

2176


Can we convert off line transformer to on line transformer

1978


Why use the vcb at high transmission system ? Why can’t use acb?

1318


Why Ac Systems Are Preferred Over Dc Systems?

1298


What is the difference between rated and per unit in transformer?

2189


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2389


What is the distance between each insulator in 33kv transformer and how can it calculate

2182


how can we calculate the ratio of caustic soda and water in lrs.

5841


before synchronizing an alternator,power factor is leading ,why?

1563


WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?

1751


how cables go in and come out for distribution from the feeder pillar box?

2083