Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why capacitor bank always connected in delta,why not in
star to a system?

Answer Posted / arvind kumawat

in the Delta connection, the phase voltage is equal to line
voltage, and in the star Connection it is 1.732 times.
The Delta Connection is Parallel wher star is series.
And the Capacitor Bank is Connected for the Power Factor
Improvement. so when connected in Delta Connection, the
Power factor can be Improved by a fixed amount.
THIS IS AS PER MY KNOWLEDGE............
ARVIND KUMAWAT

Is This Answer Correct ?    21 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between oil surge relay and buchholz relay.

6965


how works inductive &capacitive sensors?

1915


Pl.brief me any electrical major fault you have rectified.

1906


What is power relay?

1183


How we calculate the size of ht cable for any transformer

2030


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1820


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1888


what is draiv work

1839


what is transistors comprised of?

1085


What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.

8173


What are the differences between single phase and three phase?

1984


What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?

2008


Why use in ht motore

1645


IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.

2296


Why can't we take NO LOAD TRIAL of motors having V1 mounting??

1872