Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is use of 3phase instead of single phase?

Answer Posted / balaji

1.if we use all loads in a single phase voltage drop will be
high.instead of that if we use 3 phase then load will be
shared by each phases ,so voltage drop will be less.
2.we can use 3phase load as well as 1 phase load in 3phase
4wire system.

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps

1942


please send me previose rrb junior engineer qustion papers

2089


How to calculate VA rating for CT or PT or Control Transformer?

2796


Main advantage of auto transformer over two windings transformer is that A it needs no cooling B it uses only one winding C core losses are reduced D it has simple construction

2878


how to calculate the torque of a motor?

2063


what mean by analog ,digital,numerical meters and relays? say the example?

2230


how unidirectional torque is produced in DC motor?

6726


what sort of general awareness questions are asked in o.n.g.c entrance exam?????????????????

4586


What is the meaning of loop in transformer

1712


What are protections for dty type transformers

1769


what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm

5000


what is calculation mathod/formaulla for deciding Size of busbar (Copper/ aluminum)for L.T. panel on Various Fault level like 50kA,25kA,10kA

2741


How to Preparation of online test

1598


FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?

3348


What is the capacity of the Fastners 12mm?

2358