IAM GOING TO ERECT THE STREET LIGHT.,,
I NEED HOW TO CALCULATE LUX., ILLUMINATION.,AND ALL
Answer Posted / guru
There are many ways for calculation of LUX and Illumination
level. I have given you the details for Point by Point
Method for calculating the LUX requirement
LUX = (CANDELA x COS(a) x F) / D^2
Where Candela = Luminous Intensity (cd/1000lumens)
COS(a) = Required Luminous Intensity at an Angle of
(a)
D = Mounting Distance of luminairy in meters
F = Maintenance Factor
This method is generally used for Outdoor Lighting purposes
Is This Answer Correct ? | 9 Yes | 2 No |
Post New Answer View All Answers
WHY THE COLOR OF OUTDOOR TRANSFORMER IS BLUE ONLY???
what is the illumination level required for child play area?
High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?
what the Microsoft .NET framework is?
How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point
What is the numerical quantity of sqcm?
What is the actual meaning of thermal power efficiency ?
would the same effect be achieved by reversing the connection to one winding of the induction motor 3-phase?
Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.
our industries ht line so power fluctation(once drop of power please rectify causes
What are the classifications of oscillators?
HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com
How to calculate the copper in HT motors if KW, RPM & Voltage is given
what is effect of length of air gap on performance of dc motor and generator?
What is transformation ratio what it describes?