what is full form of SMART

Answer Posted / trupti

Single Module Auto Ranging Transmitter

Is This Answer Correct ?    10 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.

1085


how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?

1498


What is the use of temperature compensation?

1555


what are the steps I have to deal with?

1755


Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.

1504






what is the responsibility of an instrument commissioning supervisor

2647


What are different types of control valves?

698


what is wave length were using ?

1485


Emergency Shutdown Systems/ Plant Shutdown System.

1754


what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...

1535


Which language of programing is popular? how can i learn it ?

1716


What is 3 selection available when configure the burnout protection for controller

2075


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1452


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1430


What is cut off relay? And why use in PLC and DCS?

946