I have raw material for making Compact-Choke for flourscent
lamp of 40 Watts. We are suppose to get 0.4 amps output at
end. but we are getting 0.42 or 0.44 amps and above. We
have done many testings in different but nothing worked out.
Please suggest me how to get the correct output.

We are using 1. core winding of 700 windings of aluminium
2. E-shape iron fillings and I-shape iron fillings to
surround the winding.

Answer Posted / sunil

Chadra,
just hit smoothly on choke, then test it, most probably u
will get o.4amps, if u dont get required value then
increase the no.of wounds up to 718, and make voltage 230
(Fix the voltage on 230V.)then try it again I hope u will
get. All the best.

Could you please inform me that where are you getting the
raw material?

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why 11kv to be generated in generation station

1254


give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model

2240


how technical is calculated in 11kv line and lt line

1466


working principle a.v.r. ?

1916


in Telecom DC system-why positive +ve is made earthed.and - ve is fed to load.

2155






which of the following elements is not present in stainless steel

2028


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1201


what is the function of capacitor duty contactor in an capacitor panel???

3623


State kirchoff current law?

660


1.ZEBRA conductor(large size) 2.KUNDHA conductor( small size ) 3.panther conductor(very small ) 4.lepard conductor (very very small)

2449


what is effect of leading power facter on the system and billing

1787


What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.

2219


Dear sir, I completed DECE In the year 1995.Now i am working in a private company from last 10 years as an Electrical supervisor.The company having a 1000 KVA transformer.Now i try to apply "C" Licence. I am eligible or not.If not eligible,pls give solution.

1287


what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

1556


Dear all, I want to use Induction motor to open and close a 1 ton door. How much power do I need. Thanks

1412