Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?



Answer Posted / nilesh karpe

Rajesh & BM has ansered 1 to 12 questions:
13.first check the stroke of the valve.ie. fully open &
then full close(for checking smooth operation).
ZERO CALLIBRATION:
at full close see the demand of i/p is 4MA.& output for
this is 0.2 KG/cm2. if not adjust through ZERO pot in i/p.
SPAN CALLLIBRATION:
fully open the valve.at this time the dmd of i/p should
20MA.at this time o/p supply air should 1KG/CM2.if not
adjust the span pot in i/p.
REPEAT THE ABOVE STEPS IN TILL ZERO & SPAN READINGS
MATCH.CHECHK INTERMIDIATE POSITIONS i.e. for dmd signal of
4,8,12,16& 20MA.FOR LINEARITY CHACKING.

Is This Answer Correct ?    23 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain signal isolator

1153


can any one explain in which term we are flow flow is it volumetric r is it mass? and y

1919


Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1526


2. What is ultrasonic flowmeter?

5076


What is the PLC configuration in Cement industry?

3798


you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.

3323


How to Calibrate Interface Level Troll in field

1353


How to calibrate an pressure gauge with yantrika test bench?

2900


Which products are available in the Mass Systemswitch and System Manager AC range?

1870


In which principles tx ,pressure gauge,Temp gauge,control valve works?

1817


our kks tagging is crossing more than 12 character please suggest how to take tags in the DCS

2067


What are the type of bonnets in the control valves?

1856


Why do we floating DC in DC system.

2893


What is the purpose of the analyzer in petrochemical plant?

3864


What is 3 selection available when configure the burnout protection for controller

2690