Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?



Answer Posted / nilesh karpe

Rajesh & BM has ansered 1 to 12 questions:
13.first check the stroke of the valve.ie. fully open &
then full close(for checking smooth operation).
ZERO CALLIBRATION:
at full close see the demand of i/p is 4MA.& output for
this is 0.2 KG/cm2. if not adjust through ZERO pot in i/p.
SPAN CALLLIBRATION:
fully open the valve.at this time the dmd of i/p should
20MA.at this time o/p supply air should 1KG/CM2.if not
adjust the span pot in i/p.
REPEAT THE ABOVE STEPS IN TILL ZERO & SPAN READINGS
MATCH.CHECHK INTERMIDIATE POSITIONS i.e. for dmd signal of
4,8,12,16& 20MA.FOR LINEARITY CHACKING.

Is This Answer Correct ?    23 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?

1346


What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?

2066


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

1724


how u choose thermowell lenght n pnumatic C/v size?

2051


all types of liquid analyzer principle with drawing?

1886


HOW TO CHOOSE FREAQUENCY IN FMCW TYPE RADAR INSTRUMENTS. DESIGN BASIS OR DESIGN CALCULATONS ?

2122


How to Calibrate Level Switch in field

1256


why we are not using the turbine flow meter in the steam service?

2164


how to calculate range of level transmitter?

2259


what about your moleg in pogrees with company

2219


What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1845


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

2048


what is your eligibility criteria for freashers?

2077


What is the constant voltage unit?

1013


How many ohms are required for proper earthing?

1042