1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?
Answer Posted / nilesh karpe
Rajesh & BM has ansered 1 to 12 questions:
13.first check the stroke of the valve.ie. fully open &
then full close(for checking smooth operation).
ZERO CALLIBRATION:
at full close see the demand of i/p is 4MA.& output for
this is 0.2 KG/cm2. if not adjust through ZERO pot in i/p.
SPAN CALLLIBRATION:
fully open the valve.at this time the dmd of i/p should
20MA.at this time o/p supply air should 1KG/CM2.if not
adjust the span pot in i/p.
REPEAT THE ABOVE STEPS IN TILL ZERO & SPAN READINGS
MATCH.CHECHK INTERMIDIATE POSITIONS i.e. for dmd signal of
4,8,12,16& 20MA.FOR LINEARITY CHACKING.
Is This Answer Correct ? | 23 Yes | 0 No |
Post New Answer View All Answers
Any one can help me to identified, how can we interchange the device in FF
Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com
give me all the details about the interview and which type of question being asked
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
Q- What are the application in which PNP transistor is preferred over NPN ?
why is an oxygen sensor used in a boiler stack
Introduce yourself which is not present in your biodata?
what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
What is loop1 and loop2 in MTS LT?
please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
how to design orifice plate?what is the equation?
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
Sir,I am going to sit for IOCL written test exam. recently.Can anyone tell me the name of 'Objective type Question Book on Instrumentation Engineering ' which will help me. Pl. mail to bidyut_71@rediffmail.com / bidyut.saha2008@indiatimes.com / bidyut.saha09@yahoo.in