Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Whats meant by trivector meter where it is connected at the
substation?

Answer Posted / chandrakant sahu

Most of the Tri-Vector Meter Are basically Measure Following
Bi-Directional Parameters :
1. Phase Wise Voltage
2. Phase Wise Current with Neutral
3. Phase Wise Power Factor with Total
4. Phase Wise kW with Total
5. Phase Wise kVA with Total
6. Phase Wise kVAR with Total
7. Frequency (Avg. Frequency)
8. ToD Demand / Energy
9. Import kWH / kVAH / kVARH - Lag / kVARH - Lead
10. Export kWH / kVAH / kVARH - Lag / kVARH - Lead
11. THD

This Meters can be used LT / HT / ABT based on the Capacity
of Feeder on which this Meters are to be installed. CT / PT
Ratio can be configured for such Meters.

Is This Answer Correct ?    23 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

help me with the question that might be ask on the interview for technical position

2343


full form of electrical?

2779


Proviiding the Dedicated N earth and individual Body Earths ,Finally these all looped /Now my Question :- will it not harm in case of Transformer Fault current flows in Dediacted N Earthing to Looped Body Earthing.

2256


what is v/f control in VFD?

1594


dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish

2408


What is the meaning of HT Trivector Meter ?

2532


WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.

2211


Why hydropower is called renewable source of energy?

1101


why ss stablity limit is more transient stablity limit?

2233


if we give 60 hz single phase supply to the transformer used in europe , than what will happen

1986


Why we are going for converter transformers for DC drives application instead of distribution transformer?

2076


What is the equivalent circuit of a transformer and its vector diagram?

2721


What is mathematical model of a control system?

1203


What is the rating factor for copper cable ( Specific value according to the type of laying ) & the voltage drop?

1887


1 Ton is equal to how many watts?

1167