Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Whats the type of current and potential transformers?

Answer Posted / c.hari balakrishnan

Instrument transformers (potential & Current)used for
protection and metering purpose...Current transformers
which is used for protection is normally 5P20 class,
for differential protection i.e, PX class cts & Metering
0.2FS5 class Cts whose saturation value is very less...
For Voltage transformers 0.2 & 3P class for
metering,Protection...

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How REF protects transformer alone? explain with diagram.

1536


what are factors to be consider in electrical installation like load factor,diversity factor .....

1803


what is your majour contributions in your present job

1820


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

2096


what irequirment need to be followed when working on live equipment

1776


Why we are using only Dyn11 tranformer in distribution system but not using a Dyn1 in distributing system?why not and advantage and disadvantage in both

2721


How to megger test 11 kV cable and the acceptance IR value

2973


Why armature rheostat is kept in maximum position?

1099


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3283


Why 3 phase induction motor getting supply in body if one of it's phase is cut

1730


how to calculate the breaking capacity of different breakers.

2289


When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?

1899


how to choose cable size with respect to load? how to convert cable size in mm2 to sq.mm?

5976


How to calculate no of Lighning arrestors are required for protecting 50mX 50m*20m cubical building and locations of LA?

1835


in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain

1846