Whats the type of current and potential transformers?
Answer Posted / c.hari balakrishnan
Instrument transformers (potential & Current)used for
protection and metering purpose...Current transformers
which is used for protection is normally 5P20 class,
for differential protection i.e, PX class cts & Metering
0.2FS5 class Cts whose saturation value is very less...
For Voltage transformers 0.2 & 3P class for
metering,Protection...
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
what is booster? and how it is connected in a circuit?
if we have a industrial load of 400 kilowatts with 415 volt AC then how much total harmonic distortion (thd%) should be acceptable for steady power system.
WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI
For some transformers we are using solid neutral earthing while some others we are using resistance earthing why ?
How to calculate the multiplying factor for energy meter with ct ratio given
What do you mean by a phase angel of instrument transformer?
Please brief what is sinewave
please send me previous year questions of jspl through which i could prepare myself for the test.
hey guys i scored 910 on GRE and 67 on TOEFL respectively.I have an aggregate of about 74%in my B tech.For which colleges should i apply for an MS program in electrical engineering.I am looking for colleges in NJ,SC,NC,GEORGIA, NY. Please reply with a good response.....
How to do maintenance of transformer feeder.
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
PLEASE SEND ME NTPC RELATED INFORMATION LIKE WHICH TOPICS HAV MORE SCOPE,BOOKS TO READ,CUT OFF...PLEASE.mail at thiru.1203@gmail.com
i've iocl interview.. if you know the interview process please give me information..