Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how is efficincy of the transformer is predermined

Answer Posted / parth belani

The efficiency can be found by finding the losses. because,
efficiency= output/input = output/(output+losses)
Now there are mainly two types of losses in a transformer.
1) Iron losses which can be found by the "No load" test.
2) Copper losses which can be found by the "Full load"
or "Short Circuit" test.
by knowing the losses, and the output rating of the
transformer, we can find efficiency.

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.

2418


Explain the propagation of harmonics in the network and influence of phase angle of harmonics.

2003


please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com

2013


How to calculate capacitor bank size at a load 800kVA.

1776


i have completed deee and i've (June2012-feb 2015 experience in electrical maintenance in pvt ltd company.company having HT & LT electrical power.how to apply electrical C-license ,NOW I was resigned my job,what are requirements of applying for c-license

1777


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


why asa method ZPF method is more accurate than ASA method?

5857


How can I calculate the Mega watts required to run a plant having many electric motors and other electrical components.

2129


If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.

2136


what is the importance of Partial Dischage test for Electrical Equipments

1974


Define coil span?

1130


what does a k rating in a transformer means?

2554


I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.

1455


Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?

2196


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2941