1)we r having one problem .one dry type
transformer(6.6KV/433V)is taking high magnetizing current on
delta connected HV side of "U" phase when compared to other
two phases.could any body tell the reason why it is happening?
2)why CT secondary side protection core has got higher
winding resistance when compared to that of metering core of
same CT?
Answer Posted / tanvir s.
Answerin ur 2nd query:
As we kno the flow of current is inversely proportional to the the resistance. Hence a lower resistance winding on the metering core of the CT would ensure a sensitive/accurate current(ampere) reading. Following the same principle the protection core has high resistance to limit the flow of over current and step it down to the calibration of the metering side.
Pls feel free to correct me if i am wrong or not clear
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
what is the advantage of connecting capacitors in delta than in star?
How I calculate the ELCB for circuit breakers?
Why do not we prefer non conventional sources of energy to conventional sources?
Where is the best place to mount distribution panel in a house.
How to calculate the External Resistance required for 60HP slipring motor in case no any data of the Motor is available???
what is the differencce inn series and cascade connection??
Is RTCC panel needs any control supply.
What is the settings of distance protection relay in 400 kv line
how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............
How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
what are the different sizes of U.G. cable & where these cabl;es are used according to voltage ..
why any centrifugal blower draw more current in starting. consider id fan and fd fan?
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.