why we did not get shock by touching +ve OR -ve busbar
(Which are going to supply cell voltage) of Rectifier-
Tranformer in electrolysis plant?
Answer Posted / anshul sahu
u will feel shock if supply found earth circuit will complete if it will not find earth only then u will not feel shock
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What is the difference between isolators and electrical circuit breakers?
When distance between two pulleys is not fixed, the tension of belt is adjusted by a) driver shaft b) driven shaft c) adjustment screw d) belt
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
what are the differant std sizes of cable trenches?
CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
block diagram of 2 ups system connected in parallel mode?
What is difference between Harmonic and Non harmonic Capacitor Bank?
In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.
What is nyquist contour?
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
role of europe union in UK safety legistlation (electrical safety)
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
What type of pipe material G.I or M.S is used for sprinkler system?
Can we use shunt trip coil instead of trip coil with protection relay for protection?