what is automatic voltage regulator and it is used?
Answer Posted / jai prakash narain singh
AUTOMATIC VOLTAGE REGULATOR(AVR) IS PART OF THE EXCITATION
SYSTEM OF A ALTERNATOR,WHERE IT REGULATE THE GENERATOR
OUTPUT VOLTAGE BY INCREASING/DECREASING THE EXCITATION
CURRENT OF EXCITATION FIELD.
THE PURPOSE OF AVR IS TO BUILD UP RESIDUAL VOLTAGE TO
NOMINAL VOLTAGE LEVEL AND MAINTAIN THE NOMINAL VOLTAGE
IRESPECTIVE OF LOAD,in addition to regulating generator
voltage,the avr circuitry includes under speed and sensing
loss protection features.excitation power is directly
derived from the generator terminals.
| Is This Answer Correct ? | 7 Yes | 3 No |
Post New Answer View All Answers
HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....
I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing
can we use engine degreaser for electrical motors?
What is UPS and How do you maintain the UPS Maintenance? Brief Description on UPS maintenance.
Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me
Why you want to join non technical field when you are an engineer?
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
sir iam a 3rd yr eee student.no core company comes for recruitment to our college.my aim is to be placed in l and t.tell me the procedures.
What is BusBar integrity test and how it is conducted?
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer
why do we use 25kv supply for traction purpose?
What are the basic component of a cro?
why we use circuit breakers for switching instead of normal switching device?