As per principle we say in three phase supply ,the voltage
is producing by phase angle between two phase so two phase
is needed means then why we using three phase ?
Answer Posted / vijendra joglekar
As we know the sum of phase angle difference in poly phase
circuits will be 360 degree
i.e
Assuming that the phase R has maximum induced emf at this
instant the emf of other phase will be less then maximum value
when phase R is rotated by 120 degree in anticlockwise
direction phase Y will come in the portion of phase R and
its induced emf will be maximum further when phase R rotates
by 240 degree phase B will occupy the position of maximum emf.
Hence we have to use the three phase RY B for i mean when we
connecting poly phase circuits
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how to calculate the power factor when instantaneous voltage and current has harmonics in it ?
How to measure the earth resistance value in a concrete pavement(flood light area)?
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
how to choose cable size with respect to load? how to convert cable size in mm2 to sq.mm?
what is the interrelation between voltage current torgue speed and magnetic flux in case of different types of electric motors
What does quality factor depend on in resonance?
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
what is the difference between 2 way and 4 pole selector switch???
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?
WHY IN AC DRIVES,INPUT PHASE CURRENT SHOW UNBALANCE?
How do i right a ladder diagram that has 1 actuator that performs a full stroke followed by a half stroke
What is FM200 Gas??Applications........
What is transformation ratio what it describes?