Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is method development parameter in HPLC method
development

Answer Posted / yojana

1. Check solubility,if sample dissolved in water then use
reverse phase,othervise use normal phase.
2.wavelength selection
3.selection of mobile phase,buffer.
4. pH OF BUFFER &MOBILE PHASE
5. selection of column
6. check retention time
7 .Flow rate
8. check system suitability parameter like
i)theoritical plates
ii) Assymetry
iii) Resolution
iv) capacitor fator

Is This Answer Correct ?    31 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1649


Which is the highly polar and highly non polar column in HPLC?

2344


Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...

1750


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

849


Explain the relations between number of carbon atoms in alkanes and retention time ?

2204


why holium oxide prepared in 10% HCLO4 SOLUTION

1492


What is intact assay method development.....?

2753


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1827


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3221


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1958


Why Ethanol is Used for Standardization of GC Head space?

4264


which are the sizes of capsules?

1042


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6141


What is delay volume?

1430


how to select short coloum and long coloumn for new molecule

2522