why the armature coil in dc machine is round??
swagat k.
Answer Posted / seeu43
i think that below answer may be the answer to my
question.i m not sure please answer me.
in dc machine we know that flux from north pole to south
pole asses through the armature coil.if the armature coil
has other shape than sphere then the flux linkig will not
be uniform throughout the surface,so the emf jeneration
will also nonuniform.again sphere aquires minimum area.
so we use spherical or round armature coil.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?
Where can I get CPWD electrical specifications & Shedule of rates? Please help me
how to prepare the technical test
I am experienced with house and industrial wiring but I don't have any licence how can I apply an licence and which type of licence i can get i didn't complete deee just only experience
what is the transmission loss for electrical supply? specifically a large shopping complex where the grid is half KM away, what will the % of transmission loss? is there any transmission loss for captive unit generation for above set? thanks
WHY MOSTLY Rph IS USED FOR CONTROL CIRCUITS AUX. SUPPLY ?
What is the minimum value of hfe for the oscillations in transistorized rc phase shift oscillator?
sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence
what will happen if the prime mover on the field excitation of the on-coming generator fails?Explain.
low frequency protection why recomend?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
how is positive, negative, zero sequence is happen.. how is effect on 3 phase system
hi friend i am going too attend for hpcl in this month please help me by sending written test question papers i am in the stream of E.E.E
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V