how to convert transmitter milliamps output to like
temp,pressure etc.....
Answer Posted / mohanraj k
Milliamps output can be converted to temperature or
pressure, by means of converting the amps to volt by placing
a 250ohm resister across the circuit.
| Is This Answer Correct ? | 11 Yes | 18 No |
Post New Answer View All Answers
please tel me the calibration of pneumatic controler.
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
Give 2 application of quartz crystal used for process parameter measurement.
in differential pressure transmitter,min&max pressure range for hp&lp
sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com
Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com
What is the use of single seated valve?
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?
Which type of pressure can be measured by these elements?
what is difference between fork type and capacitance type level switch. where it is using
god evening sir i am studying m.sc(tech)electronics &instrumention.am i elegible to all industies
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
Difference between ultra sonic flow meter
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear