Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Describe: Energy efficient motors

Answer Posted / elango.kalp

energy efficent motors means losses are minimised.
1.area of cross section of conductor have been increased to
reduce copper loss.
2.thickness of lamnination has been reduced and crgo
technique has been used.
3.c3 ballbearings have been used it has good clearance
between each rollers and lubrication is proper-friction
loss is reduced
4.rotor length is increased and air gap b/w stator and
rotor is reduced- windage loss is reduced
5.plastic fan has been used

the over all efficency of energy efficient motor is 93.6%

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I COMPLITED MY B.TECH AND 10TH CLASS WITH 70%MARKS BUT 12TH CLASS 55%MARKS..CAN I GET INDIAN RAILWAY RECUREMENT EXAMINATION?

2137


How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?

1932


how to compute kvar in substation feeder to improve power factor and sending voltage

2089


Where can i get practical knowledge of solar system?

1406


Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.

1866


how to control dc motor?

1867


what is size of 3phase 4wire cable to be used for 11 ton ductable A.C and how to calculate cable size for different load

3974


What are the different types of hydro schemes?

1187


How we can change the direction of rotation of Induction motor? Prove it using graphical

2113


What are the relays in ACB and VCB

2161


how net resistance islow in star connection and viseversa in delta connection...? if anybody could explain in detail it wud be helpful.

1565


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

2216


HOW WE KNOW IN PHYSICALLY THE CONTACT SURFACE OF A VACUUM INTERRUPTER IS GOOD OR GOING TO DAMAGE IN A VCB AFTER ABOVE 500 TIMES OPERATED.

2011


what does a k rating in a transformer means?

2458


Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?

2389