How to Convert horsepower to kva?
what is the three phase formula?
explain me if u can Example..i have 50Hp Moter how can i
convert in kva tell me formula three phases
Rehan Smileavail@msn.com
Answer Posted / anil
1 L.Current xL.Volts x1.732 = KVA =
KW = HPX746
1000 PF
1000XEfficiencyxPF
2 L.Current xL.Volts x1.732XEfficiencyXPF =
KVAX1000XEfficiencyXPF = KWx 1000
xEfficiency = HP
746 746 746
When KVA know When KW know
When HP know
3 L.Current = KVAX1000 = KWx
1000 = HPX746
L.VoltsX1.732
L.VoltsX1.732XPF
LVoltageX1.732XEfficiencyXPF
| Is This Answer Correct ? | 12 Yes | 3 No |
Post New Answer View All Answers
i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?
What will happen if we introduce negative feedback to a control system that uses a positive feedback?
What is Harmonics how it is produced and what is the method to control the same
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
What are PLC leader logic program method
What should be the values of settling time, peak time, steady state error, overshoot, rise time, MPOS (Maximum percent over shoot) to keep the system in transient state, to keep the system in steady state ?
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT
why are installed water leakage detection system data centers & server rooms
what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me
a governer in an Ic engine controls the
how many types control panel of a 132/33 kv substation
define the non synchoronism of synchoronous machine in general g or m??
for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations
what is KSR type transmission tower? What is LSR type transmission tower?