how can i communicate with non-national instruments device
with pc via labVIEW8.2
Answer Posted / subramanian.s
By using DAQ6008 or DAQ6009,We can easily connect the non NI
device to PC. But, Before that you should have an
information about what type of inputs and outputs required
means that whether it's Analog or Digital. It should be note
that DAQ only Accepts -10 to 10 volts.Further details ,
Please check with DAQ6009 Catalogue.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Draw a group of instruments interlocked to a Pump & Motor?
What is the differerence between hysterisis and linearity.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
why is not useing in boiler skin thermocople
how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?
why we are using magnet for calibration of gas detector?
can any send me a forbes marshall dtron 316 manual
wich is coming the first HAZOP OR SIL
How to calibrate an pressure gauge with yantrika test bench?
what is scale factor of proximitor & unit of the vibration.
What are the interlocks we have to check during the start up of LP/HP compressor?
what is 24vdc live and dry supply
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
What types of Instrumentation Related Questions can an Interviewer ask in a Telephonic Interview ?
I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.