Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain the working principle of Synchronous Generator and
Assynchronous generator?

Answer Posted / engr arslan ghaffar

Synchronous generators are synchronous machines use to convert mechanical power to electrical power. in synchronous generator a DC current is applied to the rotor winding, which produces a rotor magnetic field. The rotor of the generator is then turned by a prime mover, producing a rotating magnetic field within the machine. this rotating magnetic field induces a three phase set of voltages within the stator windings of the generator.

Is This Answer Correct ?    26 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%

1965


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2275


for 750 kw LT load what will be the ht kva

1709


What are the advantages of speed control using thyristor?

1172


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2158


How To increase Knowledge Of boliler regarding To Only Electrical Field..

1670


Control wiring of a dol starter for forward and backward

1639


How is magnetic leakage reduced?

1232


Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?

2375


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1837


what is current check gurd relay?

2653


what is the breaking capacity and making capacity of circuit breaker and how

2178


Which is the largest hydropower station in the world?

1189


what is differentila pilot supervision in the incomer control panel in the power station?

2169


An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?

2210