Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If 440 V supply has given at the secondary winding of
transformer at that time if we apply 11 KV at primery then
what will happen???????

Answer Posted / s c budhiraja

nothing will happen if rated voltage is applied to both the
windings

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1827


How to calculate Air conditioning capacity for a telecom BTS shelter?

3499


how wecalculate breaking capcity of acb mcb mccb .explain with example

1935


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

798


how does an encoder work???

2514


WHAT IS MEANING OF Gg & Gg IN hrc FUSE

3271


by what factor the starting current is used when comparing star and delta connection for motor starting?

2064


What are the raitings of Mcb,mccb and Acb in detail ??

1606


sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.

1941


i have 500 amp inductive load of motors ,,,pleas tell me how can i calculate for capacitor bank for improving my power factor to 99 .....calcullations for capacitor bank,,,,

1601


WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?

5040


what is meant by carrier aided trip protection in transmission line

3917


why the neutral point in connnection oscillates?

2258


Dear friends I want to design busbar for1600 kva transformer(i.e2100 amps) what are all the factors to be considered before selectinga busbar what are all the standard sizes of busbars what is the formula for finding current of copper and aluminium busbar

1885


why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?

5561