Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be the earthing resistance of an industrial
substation and also What should be the house hold earthing
resistance?

Answer Posted / manoj mahajan

The Earthing Resistance of a household should not be
greater than 5-Ohm. This is in keeping with the Indian
Stadards, so also the international standards, viz, IEEE
(Institution of Electrical & Electronic Engineers) and IEC
(International Electrotechnical Commission) which stipulate
that no Earthing Resistance shall be greater than 5-Ohm.
The restriction is required to ensure the safety of the
occupants and the electrical appliances.
The Earthing Resistance of a Power Station should not be
greater than 0.5-Ohm because a Power Station is required to
carry high earth currents.
The Earthing Resistance of a Major Substation such as
a "Receiving Station" or a 400kV/220kV/110kV/66kV etc
Transmission or Stepping Up/Down Substations should not be
greater than 1-Ohm.
The Earthing Resistance of a Minor Substation such as an
11kV/230V Distribution Substation should not be greater
than 2-Ohm.
This clarifies my first answer.

Is This Answer Correct ?    104 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

pls tell me function of closing coil of A.C.B.

3341


why does a dc machine has high efficiency while working as a generator than as a motor ..

1964


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1752


wHAT IS CAPACITANCE LATCHING? hOW TO CALCULATE CAPACITANCE LATCHING? hOW TO SOLVE THE PROBLEM IF CAPACITANCE LATCHING APPLIED?

1972


how to check regenerative load in drived motor

2192


What is the difference between alternator and generator?

1267


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2630


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1830


What is center gravity load in substation?

2379


What is the percentage loss for aluminium wire for HT line more than 11KVa

2081


What is trip and closing coil in cb? Why need of them

1477


sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)

2009


What are root loci?

1057


How maesure earth neutral value & how much maximum value value required in between earth & neutral.

2042


How to calculate VA rating for CT or PT or Control Transformer?

2818