Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the function of switch gear ?

Answer Posted / sunil guru

in switch gear not all provisions but few are provided as a switch yard like.....
switching ,protections and power factor improvement with circuit breakers,relays,mccb's, contactors,capacitors and fuse units
as switch gear system is panel based system so has some limitations and other than that mainly used for meter displays purpose like V,I,p.f,kwh,frequency etc....

for any disagreement pl contact me on parmar20072008@yahoo.com

Is This Answer Correct ?    9 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is power factor why we should maintain the power factor unless what will happen

1873


Why choke coil is connected in series with starter in tubelight??why starter is connected in parallel to tubelight??

3343


difference between crane drive and line drive.

1871


What is Fire Panel ? How it works ?

2031


what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks

1861


What is sink and source?

1157


What is a difference between indoor transformer and outdoor transformer of same rating

5777


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1741


Best way to measure the Soil resistance of rocky soil, three probe method and four probe method

1909


Why the power factor improvement is so important in industrial loads

1996


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1841


typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?

1695


what is LSR?

2156


what is transient voltage?

2210


How do we calculate over and under frequency tolerance from generator data?

1582