can you suggest good traning institute in instrumentation ?
(in automation, or designing)
Answer Posted / salim
In indusries where we can see real time application of
electronic devices as well as instruments thats why ind
experince is better than to join training institute.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure
What is eddy current? Describe the operating principle of proximity probe.
What inherent design and operating principles are included in a modern control system to use predictive maintenance practices to increase overall system reliability?
Is there any relation between Artificial Intelligence and Instrumentation?
Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?
what is performance test.need defination
What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
what is the diffrence between pressure safety valve & pressure relief valve....pls
How is flow measured in square root?
How to calibrate level transmitter with use of HART?
plz send me general of ongc
Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Explain the burnout feature.
Explain the working of an electronic level troll.