In Increasing temperature why thermocouple used and RTD is
not used. Both RTD and Thermocouple have in Range of uses.
Answer Posted / pukhraj_meghwanshi
Because of Linearity. Increasing Temp. Linearity is
decrease of RTD and thermocouple linearity is increase so
it used mostly.
Is This Answer Correct ? | 38 Yes | 3 No |
Post New Answer View All Answers
Isometric drawings are generated during _________________ phase of a project
Define cryogenic?
Can anyone send most commonley asked Instrumentation questions and answers in cement industry please?
HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
List three types Level Switches with their working principles
State bernoulli’s application.
With N nodes and B branches what will have a network ???
Difference between ultra sonic flow meter
How flow can be measured with dp?
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
what effects a surging can produce in the compressor
field bus transmitter calibration procedure tell me
Explain the difference between plc and cnc?
give eg of how I/P is used in control loops