Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to select a breaker (MCB,MCCB,ELCB) for 18.5 kw, 3 ph.
480 v, 60 hz induction motor?

Answer Posted / engr ali mehmood

MCB are used for small power application; usually used in
the household appliances current rating is 5A.
MCCB are used in high power application in generation
station above 100A;Rarely used but the most common used in
industries is MPCB variable Rating of current adjust
according to the load current of the the appliances. and
the ELCB is a earth leakige circuit breaker it is use for a
body earth ground earth

Is This Answer Correct ?    27 Yes 18 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much weight an electrical engine can pull??

2150


how can i find ct ratio of meter by seeing name plate of meter and how it should be used in MF calculation if it shows only-/1???

1762


what is the effect of back reactive power on the generator ?

2259


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1938


what is doubling factor in making current of a breaker?

2114


how to design step down 12 V, 1mA small transformer from 220 V AC? Because according to VI relation and power transfer it results bulky...

2147


We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.

1995


After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.

2406


In siemens S7-300 PLC, what is function and function block ? What is the difference between them ? When to use function and when to use function block ?

3194


what is the difference between electrical choke and electronic choke?

2566


How to select the proper VSD to operate high inertial load

1788


what is the effect of power factor of machines in starting current

2111


why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points

2112


How can calculate the rating of a alternator for a given specific load with formula

2424


What is order of the system?

1179