why the CT ratio secondary is always divided by 5 for eg(
75/5,80/5,50/5)
Answer Posted / shyam
hear 5 is primary winding turns of the CT .it can be any
number not only 5
| Is This Answer Correct ? | 3 Yes | 14 No |
Post New Answer View All Answers
Is it posible to instal one more SMDB from the existing SMDB and is it practical.
how to remover corona effect and hysteresis losses from contactor
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
Hoe do calculate the Cable size for Amps rating ?
what is the advantages of having in-built acvvvf (without seperate inverter in the control panel)in the drive system of elevators?
Explain Circuit Breaker Trip Characteristics in detail.
How to convert 2 phase to 3 phase electricpower in induction moter?
Refernce currents are to be generated using refernce cueernts how can this be done??
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter
When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?
hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?