Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why induction motors are of lagging type and not leading
type

Answer Posted / iamdon

Induction motor is a singly excited machine.It means there
is no scope of power variation by varying the excitation.So
the nature of power factor is solely decided by the nature
of winding,which is moslty inductive.Thats why Induction
motor has always lagging power factor.

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    23 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Enlists the applications of sampled data systems?

1134


how to test and calculat the head and discharge in borewell compressor

2210


Please tell me the power flow from pmg to main rotor of an alternator (Including AVR unit)?

2088


What is the difference between isolators and electrical circuit breakers? What is bus-bar?

1194


What does the a,b,c of 95a,95b,95c relays denotes?

2752


Why induction motor is widely used in industry

2817


what is the prinsiple of dc motor and construction and working ,application of dc motor.

2025


When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?

2123


IN 1000kva transformer where the oil and winding temperature sensors is connected

2569


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2296


How to checked frequency drive output voltages?

1253


Why do power lines not short out when they fall into water?

2053


What is cross over distortion? How it can be eliminated?

1358


What is meant by rotor?

1342


The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.

2039