What is Single Phasing fault???(not single-phase fault)
Answer Posted / s.venkatesh
In 1 of the three phases,any of one phase was get affect
due to unbalance of cable or busbar champer with breaker
isolator connection get loose,it will reflect by no current
and less voltage on that particular phase and utilisation
of equipement also shown problem on that phases. i was
faced this problem in previous plant as from lighting
distribution panels problem..
by S.venkatesh
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
what is the clear formula to calculate cable size for a load
what is the use of the puls transformer in UPS & how it works???????????
how copper and aluminium wires or cables are choose for current rating? please provide copper and aluminium wire selection chart for different current rating ?
Is there any specialised book to refer about fault level calculation both in MV and LV side??
how the works electronic energy meter?
I AM GOING TO ATTEND APTRANSCO ON 26TH OCT 08.PLEASE SEND ME ANY MATERIAL OR TYPE OF QUESTIONS OR EXP QUESTIONS.
Is neutral transformer can be called as control transformer?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
hi, could someone help me to find a control design for syncronising panel .
What is shutdown of electrical sub station?
why capacitive load is not used in routine life????any reason is there ??????
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
how works inductive &capacitive sensors?
After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.
List examples of voltage source?