In an LT pole, the line voltage is 415V. How is it
converted to 230V into the house via the service cable?
Answer Posted / anand mishra
We can use 1ph-1neu for Covertion of 415v to 230v
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
if a.c supply is given to the motor,, what happen?
am commissioning the trafo without connecting the neutral therefore unbalance will occur what is the alternative solution for this?
in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?
What are the advantages and disadvantages of closed-loop control system?
I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?
what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT
If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive
sir i want previous entrance exam papers for written test
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
In a large office how do we calculate required number of light fittings, assuming fittings are 4x18W or 2x36W fluorescent fitting ?
how does a submersible pump work..?
Discribe type of fault in DOL and stardelta startor.
We have 110Vac ,10A ac supply which is converted into 110VDC & How much DC current? which factor is reqired for dc current calulation?