WHAT DO U MEAN BY THERMAL OVER LOAD RELAY& WHERE THEY ARE
BUSED
Answer Posted / venkatesan.j
Thermal over load relay consists of bimetallic strip made
up of two metals one having high co-efficient of expansion
and the other metal having low co -efficient of
expansion ,such that when heated up the strip starts
bending . The soource of heat is provided by the load
current in the strip.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.
What is power factor why we should maintain the power factor unless what will happen
how tto ingress mw in turbine explain.procedure ?
1.how many types of relays? 2.difference between ATS& STS?
What are the advantage of free wheeling diode in a full wave rectifier?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
Define the term Capacitance and Inductance?
What is the general power consumption rating of CPU CRT type and Flat type, Monitor,Printer, projector, Scanner?
How to define Kirchhoff current law and voltage law along with simply examples.
Witch do depand of Power factor and theory of power factor?
is it possible to test of bus bar in high rise building without completed full floor ?
what is plunger and what's the use of it in motor alignment?
Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Zone of protection and tripping scheme of arc protection relay.