Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

different between circuit breaker & switchgear & relays

Answer Posted / tareq harb

relay ca be used to protect against one fault at a time
either overcurrent or undervoltage or underfrequency but
not together, can also be used in switching & control
systems.

Breakers can be used to protect againt too many abnormal
faults in the circuit at one time.

switch gear is a series breakers connected to gether to
form a complete protected bus bar with many inputs outputs.

Is This Answer Correct ?    33 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the k var ratting of 1250kva

2098


diff. between tension mode & speed mode

2348


do we use neutral grounding for resistive balanced load? if we use what happen?

1800


Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?

2257


what are factors to be consider to design a HT & LT motor?

2327


WHAT IS DIFFERENCE BETWEEN MANUAL CONTROL AND MAGNETIC CONTROL AND STATE ITS ADVANTAGE /DISADVANTAGE

2094


what is Fan Control Cubicle

2492


how to calculate the earth fault current

2508


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

2045


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

2185


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

2327


High speed earth switch operation with diagram

2500


In convertor can we use rectifier thyristor in place of invertor thyristor with explain.

1823


What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance

2003


We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......

2196