As per the theory current doesn’t flows in Neutral, but
practically it is not applicable, explain why?
Answer Posted / arvind
because load in practical cannot be balanced, so because of
that the uneven current flows in the circuit means three
phase,neutral tries to balance the load.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
Why to keep capacitor bank off while generator running.
which type of cabel
what happen if the parallel generator phase angle shift by 1 degree in manual mode
Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.
Why line VTG = √3 phase VTG in star? How?
What is Primary And Secondary Injection Test of Relay and Other Electrical Devices. How IT is carried out.
my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?
When we giving the 3 phase supply to ups system how to coming netural?
kindly send me 11KV MV motor differential protection procedure by primary injection method.
What is a signal flow graph?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
how many synchronous motor are there in any power plant
-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.