What is the difference between Relay and Contactor
Answer Posted / a.narayanan.
RELAY IS AN ELECTRONIC OR ELECTRO MECHANIC DEVICE.IT CAN
OPERATE NORMAL OR ABNORMAL CONDITION TO TRIP THE C.B UNDER
PRESET VALUES IN ITSELF.
BUT CONTACTOR OPERATION NOT LIKE RELAY OPERATION.
IT CAN OPERATE ONLY BY CONTROL VOLTAGE IN SOME OF THE CIRCUIT.
| Is This Answer Correct ? | 16 Yes | 19 No |
Post New Answer View All Answers
How we calculat the NGR of 3phase Generator, Our generation voltage 11KV
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
Power Factor Correction Panel (Manual & Automatic)
11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter
high voltage transformer input voltage,current and amps rating..distributed transformer input voltage,current and amps rating...
I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
what is the difference between capacitive and resistive voltage divider?
what is the safety points of vaccum circuit breaker.
what is the use of commutator in dc motor if we supply ac ? commutator is used to convert ac to dc.and it is used to arrange the flux in unidirectional in case of dc supply. if we give ac as supply to dc motor what is the use of commutator?
Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?
what is the difference between circular wdg & ractangular wdg?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
Why human body feel electric shock?