Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

where we use 1 phase & 3 phase supply ?what is major
advantage using 3 phase over than single phase ?

Answer Posted / mahavir jagdev

1. lesser current (hence smaller capacity wiring) for same load

2. balance load on the bus bar

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why in ESP Positive earthed

3037


WHAT IS DIFFERENCE BETWEEN CAPACITOR AND CAPACITANCE?

1940


why any centrifugal blower draw more current in starting. consider id fan and fd fan?

1803


What is the difference b/w fanuc alpha series 16i and 18i controller. what is stand for i

2009


what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?

1901


What's the difference between non break power supply and non break non short break power supply

1398


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2091


What is the count of hvdc transmission lines in india?

1041


Name the types of motors used in vacuum cleaners, phonographic appliances, vending machines,refrigerators, rolling mills, lathes, power factor improvement and cranes.

1099


how much GROUND & NEUTRAL VOLT maintain in data center.

1989


Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????

1760


What is grid collapse? what is the reason for it?

2053


how to check avr of dg set of 125kva

2541


can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?

1999


What do you mean by cogeneration? What its working principle?

3145