If an induction motor is restarted before its rotor stop
rotating, then what will be the amount of current drawn?
Is this current will be the same as motor starting current?
Answer Posted / babu kb
induction motor takes less currunet compare that of
starting current.why because the
rotor is in running condition,(ie back emf of rotor is
'not equal to 0') "Back emf have some value while rotor is
running, so the motor takes less current compare than
starting current"
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
is there any role of power factor with frequency variation? and how we can manage the frequency variation?
What is the problem of internal failure in ship engine telegraph system norcontrol?
im working in one private compeny in gujarat. i was complet diploma electric in 2010 from gujarat technical board. now i want electric supervisor licence in gujarat but i dont't know when i apply? plz give me address of the licence dippartment office in gujarat. gandhinagar
What is the RMS and DFT principle of analogue maesurments. Which way they are advangages. where which princples give optimum results.
What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)
In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.
Why sometime AVR and sometime Booster coil is used in Alternator? what is the diferance between AVR & Booster coil due to which they are selected
Transformer cores are laminated in order to A simplify its construction B minimize eddy current loss C reduce cost D reduce hysterisis loss
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
How can we findout the maximum efficiancy of Transformer? At which load?
what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?
How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
why US countries maintains 110v and 60HZ