Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what means if slump is less than 25mm and greater than 80mm?

Answer Posted / sjtbehera

Slump test is carried out for measure workiability of
concrete. it telles about water cement ratio present in
concrete. generraly we kept this ratio is between 25 to
100mm.
slump is less than 25mm water present is very low if
greater than 80mm water present is very high.

Is This Answer Correct ?    35 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the 0 value in quantity surveying

2401


How to test cement,sand,20mmbluemetal,40mmbluemetal,bricks,concrete by visual and instrument

2161


how to calculate the rebar depth if forgot the foundation reinforcement (main steel)? is that any calculation or formula we have data sheet of supplier what depth what is the pull out capacity is mensioned in data sheet. if any IS code than its help full to me.

2634


PCC Road Min Grade M 30 for VR standard Mahatashtra load 30 KN. what should be thickness of pavement, width 4m what should be length of panel.

2579


can we find any technical issue if we are gong to change the dimensions of steel beams from one type to another type IE if there are any equievelant data base to find solution for problem of changeing sectios of beam from one type to another with the same cross sectional area.

2053


Slab quantity 

2041


how to calibrate the RM 800

2409


What is alternate bid?

1157


How will drive weight formula for circular cylinder steel bar in kg/ m please step by step drive?

2212


What is the l/d ratio of cantilever beam?

2006


What is the basic difference between OPC

2073


The building has 12 columns of 12x9 in 3 rows of 4 each in a plot of 50'x30', The central row is strengthened with 16mm twisted rods. The roof area is 1500 sft including balconies. calculate the load factor per sft. Also indicate the number of roofs the building can withstand.

2732


How to activate isometric axes in cad?

1233


Explain what is 1/8 on the architect ruler denotes?

1164


what is the method used for marking of cantilevers in hirise buildings by using theodolite

2943