which trsanmission is easy and cost effective AC or DC.
Answer Posted / anbuselvan
Both AC and DC has its own Merits and demerits.
But Based on Installation,Maintenance and Efficiency, DC is
best than AC.
Bcaz, in AC has Many Trans Losses,Its required much copper
or Alumin for each line.But in case of DC need not to have
much copper, lesser Trans Losses.
In DC its required Converter and Inverter with heavy
rating.but nowdays its very popular and working more
effective and efficiently.therefore the conversion process
is not much complicated.
In Electrical engineering, our main objective is to transfer
the Power with high efficiency(i,e.,Min loss).
So Upto my knowledge DC is better than AC.
Thank you
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
how to differentiate a mpcb,mcb with a contactor? Explain their working operation
Pls explan the OLR setting in VCB at HT yard
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
HELLO SIR, IAM PREPARING HPCL EXAMS. SO PLS SEND MATERIAL OF HPCL ELECTRICAL ENG..TO VIJAY_8888@YMAIL.COM
before transformer oil dielectric strenght tests are taken the oil should be allowed to settle to remove option 1 air bubbles 2 gasses 3 contamination 4 water
how to estimate wiring ins roughing ins. and boxes
Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?
If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?
Why the symbol of register is "zig zag"
How we can come to know the substation range,without go through any name plate ?
what is per unit calculation?looking for simple and strong explanation thk u
how solar power plant energy meter multiplication factor
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
IN electrical field, WHAT ALL THINGS THE CUSTOMER WILL ASK WHILE ORDERING FOR LT PANEL (ALL TYPES OF LOW TENSION PANEL)
Dear all, I want to use Induction motor to open and close a 1 ton door. How much power do I need. Thanks