what is the difference between power and distribution
transformer?

Answer Posted / latika

Distribution transformers have LV side with 440/220V which
distributes the power to promises, shops, industries and
offices. So it is conventionally called distribution
transformer. 440V/ 220V are the Indian Standard dist.
voltage with 50HZ Freq. So in India transformer with LV side
having output of 440/220V is generaly called distribution
transformer. All others are power Transformer.

Is This Answer Correct ?    6 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?

1432


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

1557


how to select proper cable for ct wiring so that drop within the limit.

1466


Which thing is maximum in RLC circuit at resonance a)power consumption b)inductive current c)capacitive voltage

1339


what are the disadvantages in GIS over AIS

1928






Explain advantages of storage batteries

655


what is the meaning of number in (11, 31, 61,14, etc. CDG11, CDG31, CDG61, DDT32

911


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3377


What is mean by STUB protection?

1582


v/f drive basic princeple

2004


what is meant by tranformer impedance?

2164


1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor

4278


why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.

2628


How many Zones can be in Conventional type fire alarm system & how can we detect the fire in Conv. type FAS?

1381


A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2026