Why is the electric shock from the DC supply is more
dangerous than the shock from AC supply.
Answer Posted / anand
220 dc mean 220dc..
but 220ac mean rms valu which is less than 220..
thats why dc is dangerous..
| Is This Answer Correct ? | 0 Yes | 4 No |
Post New Answer View All Answers
State any two nuclear power stations in India, with their generating capacity.
how power is generated,and transmitted to our home..pls explain briefly in simple words.
TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.
take 100kva DTR( delta/wye ), what ll happen if we connect 11kv to LT side instead of connecting to HT side? will the DTR behave as a step up transformer or something else????
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
what is meant by class 1 E in electrical power supply?
why we use 630mm single core cable for transformer secondary side and why two neutral cable
A system absorbs 100 k J of heat and the increase in its internal energy is 100 kJ; the work done is
what is the major difference between LIBBP & HIBBP.. which one is most preferable..
What do you mean by the zone of protection?
What is the function of interposing current transformer?
It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.
Explain the operation carried out in thermal power stations?
We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?
What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?