In which type of circuit short circuit is dangerous in
parallel or series and why?
Answer Posted / vksumanth
ph-------o-------o-----o------n
in the above fig shows series combination, if any short occur in the circuit current increases and fail starting element only ckt opened.
-------o---------/
/ parallel /
/------o---------
u r understanding from above fig suppose branch1 element may short occur current raised in that branch ,because v same i not same.remaining ckt healthy.
SO IAM TELLING CLEARLY DANGER IS SAME ABOUT LOSSING OF APPARATUS.BUT IN PARALLEL ONLY SHORT BRANCH DAMAGED AND INTRUPTED REMANING BRANCHES OK.GOOD
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?
If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.
HOW TO CALCULATE AMPs OF CURRENT TRANSFORMER IN HT Panel
How the capacitance og capacitor volatage transformer is decided?
sail kaott diploma ece ke interviw me qus.kis parkar ke aate hai aur G.S me kya puchate hai kya sameedyaan me kis parkar ke qu.puchate hai
Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job
What is the voltage gain or transfer function of amplifier?
Why can't we parallel the secondary circuits of two voltage transformers?
What is the effect of positive feedback on stability of the system?
why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points
for what purpose the star point is done in ct
3ph motor running with unequal kw and different pf what are the reasons
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
I want the details about BHEL company examination.Can anyone able to help me please.
Why colled 440V to 3-phase supply.