Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the safe meggar values for motor, transformer HT, LT
and Cables?

Answer Posted / akshay grover

Megger guys say, the value shall be


Megger Value (in Meg Ohms) = (system Voltage + 1)/ 1000

Is This Answer Correct ?    30 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer

1792


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9449


how oltc works in rectiformers of higher rating (27 mva,200v dc,120kamps) please provide me full information with diaggram.

2183


How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.

2266


What is the difference between isolators and electrical circuit breakers? What is bus-bar?

1191


Why PS class CT is always preferred for Differential protection?

1673


single phase power supply give to separate one steel coup with water, what reaction create

2133


Explain cos(theta) and Sin(theta)

2158


What is the difference between Encoder and Resolver?

3602


how desiel generate sart fail of eb?

2249


how we calculate torque ? how we improve it ?where torque will either motor or generator ?

2116


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2117


what is load vs Torque curve & why it is used?

2123


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

2005


What is the diffrence (Technical & Construction ) between CBCT & Normal CT?

2084