Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the safe meggar values for motor, transformer HT, LT
and Cables?

Answer Posted / ssreenu

megger value varies based on voltage of the system. If I
assume it is a 440 Volts system the megger value should be
min. 1 mega ohm.

Is This Answer Correct ?    72 Yes 29 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?

2125


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.

1821


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

2043


Dyn1 transformer vector group testing how to do

1807


i need the details about bhel exam.how to apply for that.please send to my email-id.thenmozhi2k7@gmail.com

2020


How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

1776


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2747


For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?

1951


How to calculate capacitor bank size at a load 800kVA.

1717


what are the specifications we must look at to select a relay for any capacity motor?

2042


how the CT and PT is connected in the circuit during testing of transformer explain with diagram

2028


How can I known multiplying factor .without multiplying table

1800


why we use single core 630mm2 cable for transformer secondary side

929


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1878


What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?

1854