the distance from my office to d.g is aprox 400mtrs and
voltage drops ibn my office near about 40 volt what should
i do p[ls suggest.
Answer Posted / anand
mr . sree ur ans wrong nobodie use capacitors in dg power.
mr.Duttgaurav pls re size the caple r use thevoltage
regulator
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
how to differentiate a mpcb,mcb with a contactor? Explain their working operation
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
Graphs of measuring power and speed on dc motor
working principles of cf lamp,incandescentlamp and f lamp?
Explain Random and Deterministic signals?
how to select fuse rating for a 3-phase motor ???
Installation method of self treated earth electrode.
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
During underground cabling in landscape area what did we cover the cable with to prevent the electric shock & protect the cable?
WHAT IS MEANT BY INSULATION CLEARANCE IN VACCUM?
Why the symbol of register is "zig zag"
1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
Why efficiency of generator is higher than motor at a particular load?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...