Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

i Have 1000kva 11/.4 kv voltemp make t/f Its a 2 year old. i
wants to known how much iron losses & copper loses during no
load condition.

Answer Posted / pavankumar

copper losses are zero ideally but iron losses are constant

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1389


what is the difference between RMS & TRUE RMS VOLTAGE

2894


What is the drawback of static coefficients?

1555


State ohm’s law?

1067


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2094


CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)

1804


What is synchro?

1126


We have given to 3phase supply to ups system & how can coming netural

2117


Please brief what is sinewave

2114


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1357


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1838


Why is the frequency not changed during transformation of electrical energy in a transformer?

1352


What is load boxes ?

2114


What is bridge rectifier and explain with details

1885


How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter

7684