What is the basic principal of Diesel genarator?
Answer Posted / milinda4p
the generator is coupled with a shaft of a diesel engine.
when engine is on the shaft is driven at a specific speed to get
the required frequency. so the prime mover of the generator is
ont directly coupled with the shaft of the engine but through
some gear wheel mechanism
| Is This Answer Correct ? | 5 Yes | 29 No |
Post New Answer View All Answers
why h parameter are called as hybrid parameter?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
What Is HO factor in power selection
What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?
Please explain me abt PQ diagaram in the power sector.
why single CT used in DOL starter power circuit?
What is the difference between solid grounding and impedance grounding?
what is relay what is protection & contact multiplying relays where it is used function in brief
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?
An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.
in power generator normaly voltagr betwween esth to neutral is 0 but my work place generator show the volatge is 60v any body know why? thanks
What is the difference between isolators and electrical circuit breakers?
why we use two slope(differential & restraining) in differential relay.but in busbar protection differential we are using only one slope?please explain
100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.