Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is scan time of PLC & in which factor scan time is
decide

Answer Posted / mprajaneb

Scan time depends on PLCs. In the timing diagram of PLC
execution we have three different times.
1. Input scan time
2. Execution time
3. Output scan time.
Input scan time the PLC receiving the data status from the
input peripherals.
Execution time is the time required to execute the program
or for scanning the rungs in PLC program.
Output scan time is the time required to send the results
to the output devices as per the execution of the program
rungs.

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is destructive and non-destructive testing of welding

1662


what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator

2031


How to calculate impedance volt in Transformer?

2080


How much ph is maintained of water resistance starter for slipring induction motor ?

2402


Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output

1829


What do you mean by Stimulastion Test in Diesel Genarator / Why & when it's conducted ?

1643


How to calculate capacitor bank size at a load 800kVA.

1701


what is cogging and crawling

2527


How vfd saving power.

2022


Define ohm’s law for a.c (alternating current)?

1037


IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?

4122


Plz tell me how we can find that particular company has vacancy or not

2266


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.

1989


Why magnetic flux produces an induced current?? what is the detailed procedure ?? ans plz

3907


Why arc quenching is used in Diode ?

2144