how to check the 3ph capacitor is good or not.
Answer Posted / mohamed
check the Cpacitor Rating ( KVR) and put in the Clamp
meter take Amps
For Example = 25 KVR Capacitor
= 34 Amps ( good Condition)
| Is This Answer Correct ? | 19 Yes | 6 No |
Post New Answer View All Answers
which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?
hi this is hema, r there any books in particular for the preparation of the APPSC-A.E.E(electrical), if so please mail me the names ... thank u .
what is meant by 3rd hormonics ?
What is an alternator impedance value?
why r we using shell transformer for low voltage
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......
What is the diffrence (Technical & Construction ) between CBCT & Normal CT?
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%
As you achieve greater success with the company after some years, Will you like to be a share holder in our company?
What types of question are done for diploma students in aptitude test
in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?
A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?
Draw a SLD of DG distribution up to main LT panel?