Answer Posted / percy
nuetral is provided for zero sequence current
Ground is provided for safety( it allows the fault current
to flow through the ground)
| Is This Answer Correct ? | 5 Yes | 2 No |
Post New Answer View All Answers
what is the differencce inn series and cascade connection??
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
State magnitude criterion.
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
What type of core material is used for metering C.T and protection C.T???
Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.
How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?
what will happen if OLR CT in all phases are short circuted
why we have to particulary use ACB for below ratings,even available of MCB,MCCB with that range ?
what will happen when the dc supply is given to the capacitor?
what is meant by 3rd hormonics ?
how to decide choke rating for drive?
what is the advantage of connecting capacitors in delta than in star?